Specifications.
Maximum cooling capacity = 66 kW. Water consumption for 24 S9 in acceleration (60 kW) = 1.2 m3 / h. Electrical connection = 5 x 35mm2 (copper conductors). Water connection = 3/4 inch (mains running water). Electricity consumption per pump = 0.345 kW. Tank for the heating medium = 240 liters. Assembled weight (without coolant) = 99 Kg. Overall dimensions with a lid (lxwxh) = 1890x875x450 mm.
Basic equipment.
Tank plastic or metal (stainless steel). For 4 cells. Circulation pump. Brazed heat exchanger. Heat carrier (liquid STE Crystal 70T or PMS-10). Electric panel, automatic devices, RCD, low current. Coarse filter. Plumbing piping. Temperature sensor (thermostat) - at a critical temperature switches off the unit by itself. After cooling, it turns on automatically. Liquid sensor - shuts down the unit in case of leakage. Fan emulators.
Additional equipment
Switch. Router. Power supplies (PSU) for overclocking 2.5-3kW. Special firmware for fan emulation, chip tuning, energy efficiency and overclocking up to 21Th. Arduino for ASIC miner control and remote control.
Detailed description
The installation is designed for heat removal 240 MJ or 66 kWh of electricity. For example, 24 Antminer S9 x 2.5 kW (power including overclocking) = 60 kW. At the same time, the installation itself consumes 0.345 kW for the operation of the circulation pump. It is connected to a cold water source up to 20 degrees. celsius. This can be network (tap) water, water from a reservoir (river, pond, lake), a well or a closed circuit, which, in turn, has many options (pipes laid in the ground, return of network water to the main through a bypass, heating etc.) With a typical electricity consumption of up to 60 kW / h, approximately 1.2 m³ of water per hour is required. The unit is electrically connected with a 35 mm² cable x 5 copper conductors. In the power panel, the cable is protected by a 100 amp circuit breaker and an RCD or a 100 amp difavtomat. In the standard switchboard of the installation, the cable is connected to three contactors (each phase for one contactor) that turn on / off the power machines for powering the miners. There are 24 power machines in total, one machine for 1 ASIC miner. Also in the dashboard there are machines for the control circuit, pumps and a block of four sockets for connecting a network switch (switch), a computer, etc. On the water, the installation is connected with a flexible hose. The heat exchanger connections have a 2 ”male thread, so reducing sleeves may be required depending on the cooling option you choose. To connect to the mains water supply, a flexible 3/4 inch hose is sufficient. In other cases, we will advise you if necessary. It is advisable to put an oblique filter at the inlet for coarse water purification and a valve for smooth adjustment of the water supply to the heat exchanger. The volume of the cold water supply will determine the temperature of the heating medium in the installation. The recommended coolant temperature is 50-65 degrees for Antminer S9 (for other equipment, it may differ). The unit is equipped with overheating protection. The thermostat is set to 68-72 degrees. Thus, when reaching 72 degrees, the unit will be de-energized. After cooling to 68 degrees, it will turn on automatically. At the request of the user, the off / on threshold can be changed, but we do not recommend setting it above 80 degrees. It is also provided for the shutdown of the installation in the event of a drop in the coolant level in the installation below the critical one. Photolist 1 Photolist 2 GO.
Request a priceDo you want to cooperate with us?
We offer our partners beneficial cooperation
Asicdip offers special partnership terms for owners and administrators of large mining farms. For wholesalers, mining equipment and major repair services!
As a partner you will receive: